IPS:
Interface:
Ethernet: 2 x 10/100/1000BaseT(X) Ports (RJ45 Connector), 1 x 10/100/1000BaseT(X) MGMT Port (RJ45 Connector)
Serial: 1 x RS-232 Console Port (USB Type-C connector)
Buttons: Reset button
Digital Input Channels: +13 to +30 V for state 1, -30 to +3 V for state 0, Max. input current: 8 mA
LED Indicators: PWR1, PWR2, STATE, BYPASS, USB
Alarm Contact Channels: Resistive load: 1 A @ 24 VDC
DoS and DDoS Protection:
Technology: ARP-Flood, FIN Scan, ICMP Flood, TCP Sessions Without SYN, NMAP-ID Scan, NMAP-Xmas Scan, Null Scan, SYN/FIN Scan, SYN/RST Scan, SYN-Flood, Xmas Scan
Software Features:
Management: Not specified
Authentication: Not specified
Firewall:
Filter: DDoS, Ethernet protocols, ICMP, IP address, MAC address, Ports
IPS Throughput: Not specified
Latency: Not specified
Intrusion Prevention System: Enabled by default. IPS pattern update functionality requires an additional license
Deep Packet Inspection: Modbus TCP, Modbus UDP, DNP3, IEC 60870-5-104, IEC 61850 MMS, EtherNet/IP, Omron FINS, Siemens S7 Comm., Additional protocols will be supported through future firmware updates.
Policy Enforcement Rules: Not specified
ICS Protocol Filter Profiles: Not specified
Throughput: Max. 45K packets per second / 500 Mbps (based on RFC 2544)
Real-Time Firewall / VPN Event Log:
Event Type: Firewall events, Protocol DPI, and IDS/IPS events
Media: Syslog server, Local storage, SNMP Trap
Power Parameters:
Connection: Removable terminal block
Input Voltage: 12/24/48 VDC (Redundant dual inputs)
Input Current: 0.69 A (max)
Reverse Polarity Protection: Supported
Physical Characteristics:
Housing: Metal
Dimensions: 35 x 125 x 100 mm (1.38 x 4.92 x 3.94 in)
Weight: 385 g (0.85 lb)
Installation: DIN-rail mounting, Wall mounting
Operating Temperature: -40 to 75°C (-40 to 167°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Standards and Certifications: Safety: IEC 62368-1, UL 62368-1; EMC: EN 55032/35; EMI: CISPR 32, FCC Part 15B Class A; EMS: IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV, IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m, IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV, IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV, IEC 61000-4-6 CS: 10 V, IEC 61000-4-8 PFMF; Railway: EN 50121-4; Traffic Control: NEMA TS2; Shock: IEC 60068-2-27; Freefall: IEC 60068-2-32; Vibration: IEC 60068-2-6; Telcordia (Bellcore), GB
MTBF: 2,929,641 hrs